Narol Ahmedabad, Gujarat
GST No. 24AAHFR1656G1ZA
Call 0804383974594% Response Rate
Send Enquiry






| Minimum Order Quantity | 100 Meter |
| Cable type | K type |
| Conductor size | 7/36 |
| No of cores | 2 core |
| Insulation material | Fiberglass |
| Sheath material | SS braided |
| Cable rating | 400°C to 500°C (standard range) |
| Thermocouple Type | K-Type |
| Material | Fiberglass |
| Temperature | Upto 1200 C |
| Accuracy | Class 1 |
View Complete details





| Minimum Order Quantity | 200 Meter |
| Thermocouple Type | K |
| Conductor Size | 1/26 |
| Insulation Material | PTFE |
| No. Of Cores | 2 Core |
| Shielding | Braided Shield |
| Temperature Range | -200°C to 1260°C |
| Material | Fiberglass |
| Size | 20, 21, 22, 24, 26, 30, 36 Customization possible |
| Conductor Material | Copper, Nickel, Alloys, etc. |
| Application | Industrial |
View Complete details






| Minimum Order Quantity | 10 Piece |
| Sheath material | SS316 |
| Class | Class 1 |
| Probe length | 100 mm |
| Probe Material | Stainless Steel |
| Accuracy | +/- 1.5 deg C or +/- 0.4% |
| Probe diameter | 4 mm |
| Insulation | FG/FG/SS |
| Junction type | Grounded |
| Temperature Range | -200 to 1250 deg C |
| Material | Stainless Steel |
View Complete details




| Minimum Order Quantity | 10 Piece |
| Sheath material | SS316 |
| Class | Class 1 |
| Probe length | 300 mm |
| Accuracy | +/- 1.5 deg C or +/- 0.25% |
| Probe Material | Stainless Steel |
| Probe diameter | 8 mm |
| Insulation | FG/FG/SS |
| Junction type | Grounded |
| Temperature Range | 0 to 1300 deg C |
| Application | Industrial |
View Complete details





| Minimum Order Quantity | 100 Meter |
| Thermocouple Type | KX |
| Conductor Size | 1/22 |
| Insulation Material | Fiber Glass |
| No. Of Cores | 2 Core |
| Shielding | FG/Asbestos |
| Temperature Range | -200 to 1260°C |
| Conductor Type | Copper |
| Temperature | 0 to 1250°C |
| Accuracy | Class 1 |
| Cable Color | Yellow |
Thermocouple asbestos wire refers to thermocouple extension or compensating wires that are insulated with asbestos Fiber, which was historically used due to its excellent heat resistance, electrical insulation, and durability in harsh environments.
Important Warning
Asbestos is a known carcinogen, and its use is now highly restricted or banned in many countries due to serious health risks (e.g., asbestosis, mesothelioma, lung cancer). Most modern applications have replaced asbestos with safer alternatives such as fiberglass, ceramic Fiber, or mineral insulation.
Description (for historical or legacy context):
Modern Alternatives:
Due to health and regulatory concerns, the following materials are now preferred:
Summary Table
|
Feature |
Thermocouple Asbestos Wire |
|
Insulation |
Asbestos Fiber or braid |
|
Temperature Range |
0°C to 1260°C |
|
Conductor Types |
Type K, J, T, etc. |
|
Hazard |
Health risk due to asbestos exposure |
|
Modern Status |
Obsolete / Banned in most countries |
View Complete details







| Minimum Order Quantity | 100 Meter |
| Thermocouple Type | K |
| Conductor Size | 7/36 |
| Insulation Material | PTFE |
| No. Of Cores | 2 Core |
| Shielding | Braided Shield |
| Temperature Range | -200°C to 1250°C |
| Shielding Type | Shielded |
| Temperature | -200 to 1250°C |
| Outer Sheath Material | PTFE |
| Country of Origin | Made in India |
Construction & Materials
A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:
|
Component |
Material / Type |
Purpose / Notes |
|
Conductor / Core wires |
Nickel-Chromium (Positive) Nickel Aluminium (Negative) |
The thermoelectric pair that produces a voltage proportional to temperature difference |
|
Insulation around each core |
Fused PTFE (Teflon) |
Electrically isolates the wires; protects from moisture, chemicals, abrasion |
|
Outer jacket / sheath (optional) |
FEP, braided shield, or Teflon outer jacket |
Additional protection, shielding, mechanical strength |
|
Shield / braid (optional) |
Tinned copper or stainless-steel braid, over or under jacket. |
To reduce electromagnetic interference (EMI) / noise pickup |
View Complete details






| Minimum Order Quantity | 100 Meter |
| Cable type | N type |
| Conductor size | 7/36 |
| No of cores | 2 core |
| Class | Class 1 |
| Conductor Type | N Type |
| Color | Orange |
| Insulation material | PTFE |
| Sheath material | PTFE |
| Cable rating | -65°C to 240°C |
| Temperature | -270°C to 1300°C |
View Complete details




| Minimum Order Quantity | 100 Meter |
| Cable type | K type |
| Conductor size | 0.55mm |
| No of cores | 2 core |
| Insulation material | PTFE |
| Sheath material | Braided PTFE |
| Cable rating | 250 C |
| Shielding | Braided |
| Brand | Radiant |
Construction & Materials
A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:
|
Component |
Material / Type |
Purpose / Notes |
|
Conductor / Core wires |
Nickel-Chromium (Positive) Nickel Aluminium (Negative) |
The thermoelectric pair that produces a voltage proportional to temperature difference |
|
Insulation around each core |
Fused PTFE (Teflon) |
Electrically isolates the wires; protects from moisture, chemicals, abrasion |
|
Outer jacket / sheath (optional) |
FEP, braided shield, or Teflon outer jacket |
Additional protection, shielding, mechanical strength |
|
Shield / braid (optional) |
Tinned copper or stainless-steel braid, over or under jacket. |
To reduce electromagnetic interference (EMI) / noise pickup |
View Complete details





| Minimum Order Quantity | 100 Meter |
| Cable type | K type |
| Conductor size | 7/0.2 mm |
| No of cores | 2 core |
| Insulation material | PTFE |
| Sheath material | PTFE/PTFE |
| Cable rating | 250 C |
| Shielding | Braided |
| Brand | Radiant |
Construction & Materials
A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:
|
Component |
Material / Type |
Purpose / Notes |
|
Conductor / Core wires |
Nickel-Chromium (Positive) Nickel Aluminium (Negative) |
The thermoelectric pair that produces a voltage proportional to temperature difference |
|
Insulation around each core |
Fused PTFE (Teflon) |
Electrically isolates the wires; protects from moisture, chemicals, abrasion |
|
Outer jacket / sheath (optional) |
FEP, braided shield, or Teflon outer jacket |
Additional protection, shielding, mechanical strength |
|
Shield / braid (optional) |
Tinned copper or stainless-steel braid, over or under jacket. |
To reduce electromagnetic interference (EMI) / noise pickup |
View Complete details





| Minimum Order Quantity | 100 Meter |
| Thermocouple Type | K |
| Cable type | K type |
| No of cores | 2 core |
| No. Of Cores | 2 Core |
| Sheath material | Braided FG |
| Temperature Range | 0 to 1250°C |
| Cable rating | 0 to 1250°C |
| Shielding | Braided |
| Conductor size | 1/30 |
| Insulation material | FG/FG |
Construction & Materials
A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:
|
Component |
Material / Type |
Purpose / Notes |
|
Conductor / Core wires |
Nickel-Chromium (Positive) Nickel Aluminium (Negative) |
The thermoelectric pair that produces a voltage proportional to temperature difference |
|
Insulation around each core |
Fused PTFE (Teflon) |
Electrically isolates the wires; protects from moisture, chemicals, abrasion |
|
Outer jacket / sheath (optional) |
FEP, braided shield, or Teflon outer jacket |
Additional protection, shielding, mechanical strength |
|
Shield / braid (optional) |
Tinned copper or stainless-steel braid, over or under jacket. |
To reduce electromagnetic interference (EMI) / noise pickup |
View Complete details






| Minimum Order Quantity | 100 Meter |
| Cable type | K type |
| Conductor size | 7/0.2 mm |
| No of cores | 2 core |
| Insulation material | FG/FG/SS |
| Sheath material | SS braided, upto 1200°C |
| Cable rating | -200°C to 1260°C |
| Shielding | Braided |
| Brand | Radiant |
Construction & Materials
A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:
|
Component |
Material / Type |
Purpose / Notes |
|
Conductor / Core wires |
Nickel-Chromium (Positive) Nickel Aluminium (Negative) |
The thermoelectric pair that produces a voltage proportional to temperature difference |
|
Insulation around each core |
Fused PTFE (Teflon) |
Electrically isolates the wires; protects from moisture, chemicals, abrasion |
|
Outer jacket / sheath (optional) |
FEP, braided shield, or Teflon outer jacket |
Additional protection, shielding, mechanical strength |
|
Shield / braid (optional) |
Tinned copper or stainless-steel braid, over or under jacket. |
To reduce electromagnetic interference (EMI) / noise pickup |
View Complete details




| Minimum Order Quantity | 100 Meter |
| Cable type | K type |
| Conductor size | 3/24 |
| No of cores | 2 core |
| Insulation material | FG/Asbestos |
| Sheath material | Asbestos |
| Cable rating | 400 C |
| Shielding | Braided |
| Brand | Radiant |
Construction & Materials
A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:
|
Component |
Material / Type |
Purpose / Notes |
|
Conductor / Core wires |
Nickel-Chromium (Positive) Nickel Aluminium (Negative) |
The thermoelectric pair that produces a voltage proportional to temperature difference |
|
Insulation around each core |
Fused PTFE (Teflon) |
Electrically isolates the wires; protects from moisture, chemicals, abrasion |
|
Outer jacket / sheath (optional) |
FEP, braided shield, or Teflon outer jacket |
Additional protection, shielding, mechanical strength |
|
Shield / braid (optional) |
Tinned copper or stainless-steel braid, over or under jacket. |
To reduce electromagnetic interference (EMI) / noise pickup |
View Complete details




| Minimum Order Quantity | 100 Meter |
| Cable type | K type |
| Conductor size | 3/26 |
| No of cores | 2 core |
| Insulation material | FG/FG/SS |
| Sheath material | SS braided |
| Cable rating | upto 1200°C |
| Brand | Radiant |
Construction & Materials
A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:
|
Component |
Material / Type |
Purpose / Notes |
|
Conductor / Core wires |
Nickel-Chromium (Positive) Nickel Aluminium (Negative) |
The thermoelectric pair that produces a voltage proportional to temperature difference |
|
Insulation around each core |
Fused PTFE (Teflon) |
Electrically isolates the wires; protects from moisture, chemicals, abrasion |
|
Outer jacket / sheath (optional) |
FEP, braided shield, or Teflon outer jacket |
Additional protection, shielding, mechanical strength |
|
Shield / braid (optional) |
Tinned copper or stainless-steel braid, over or under jacket. |
To reduce electromagnetic interference (EMI) / noise pickup |
View Complete details





| Minimum Order Quantity | 100 Meter |
| Cable type | K type |
| Conductor size | 7/36 |
| No of cores | 2 core |
| Insulation material | Fiberglass |
| Sheath material | SS braided, FG/FG/SS |
| Cable rating | Up to 1250°C |
| Shielding | Braided |
| Brand | Radiant |
Construction & Materials
A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:
|
Component |
Material / Type |
Purpose / Notes |
|
Conductor / Core wires |
Nickel-Chromium (Positive) Nickel Aluminium (Negative) |
The thermoelectric pair that produces a voltage proportional to temperature difference |
|
Insulation around each core |
Fused PTFE (Teflon) |
Electrically isolates the wires; protects from moisture, chemicals, abrasion |
|
Outer jacket / sheath (optional) |
FEP, braided shield, or Teflon outer jacket |
Additional protection, shielding, mechanical strength |
|
Shield / braid (optional) |
Tinned copper or stainless-steel braid, over or under jacket. |
To reduce electromagnetic interference (EMI) / noise pickup |
View Complete details







| Minimum Order Quantity | 100 Meter |
| Thermocouple Type | KX |
| Conductor Size | 3/26 |
| Insulation Material | Fiberglass |
| Conductor Type | Solid |
| No. Of Cores | 2 Core |
| Shielding | Braided Shield |
| Temperature Range | -200 to 1250°C |
| Usage/Application | Electric |
| Outer Sheath Material | SS Braided |
| Country of Origin | Made in India |
View Complete details







| Minimum Order Quantity | 100 Meter |
| Thermocouple Type | K |
| Conductor Size | 7/36 |
| Insulation Material | Fiber Glass |
| No. Of Cores | 2 Core |
| Shielding | FG/FG/SS |
| Temperature Range | -200°C to 1250°C |
| Shielding Type | Shielded |
| Conductor Type | Solid |
| Temperature | -200 to 1250 deg C |
| Cable Color | Yellow |
View Complete details