Our product range includes a wide range of thermocouple cable / temperature cable, thermocouple wires cables, k type thermocouple sensor, s type thermocouple sensor, compensating asbestos cable and k type thermocouple wire teflon coated.

Thermocouple Cable / Temperature Cable

  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 18 / MeterPrice on Request
Minimum Order Quantity100 Meter
Cable typeK type
Conductor size7/36
No of cores2 core
Insulation materialFiberglass
Sheath materialSS braided
Cable rating400°C to 500°C (standard range)
Thermocouple TypeK-Type
MaterialFiberglass
TemperatureUpto 1200 C
AccuracyClass 1
We are a unique entity in this industry, actively engaged in offering a premium quality array of Thermocouple Cable.

View Complete details

Yes! I am InterestedRequest a call back

Thermocouple Wires Cables

  • Product Image
  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 21 / MeterPrice on Request
Minimum Order Quantity200 Meter
Thermocouple TypeK
Conductor Size1/26
Insulation MaterialPTFE
No. Of Cores2 Core
ShieldingBraided Shield
Temperature Range-200°C to 1260°C
MaterialFiberglass
Size20, 21, 22, 24, 26, 30, 36 Customization possible
Conductor MaterialCopper, Nickel, Alloys, etc.
ApplicationIndustrial
We are a reputed name in the industry, devoted towards offering the best quality array of Thermocouple Wire And Cables.

Features:
  • Enhanced durability
  • Highly durable
  • Excellent tensile strength
We are a reputed name in the industry, devoted towards offering the best quality array of Thermocouple Wire And Cables

Features:
  • Enhanced durability
  • Highly durable
  • Excellent tensile strength

View Complete details

Yes! I am InterestedRequest a call back

K Type Thermocouple Sensor

  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 450 / PiecePrice on Request
Minimum Order Quantity10 Piece
Sheath materialSS316
ClassClass 1
Probe length100 mm
Probe MaterialStainless Steel
Accuracy+/- 1.5 deg C or +/- 0.4%
Probe diameter4 mm
InsulationFG/FG/SS
Junction typeGrounded
Temperature Range-200 to 1250 deg C
MaterialStainless Steel
A Type K thermocouple refers to any temperature sensor containing Chromel and Alumel conductors, that meets the output requirements as stated in ANSI/ASTM E230 or IEC 60584 for Type K thermocouples. This may be an immersion sensor, a surface sensor, wire or another style of sensor or cable
Temperature Range: upto 1250 degree celcius

View Complete details

Yes! I am InterestedRequest a call back

S Type Thermocouple Sensor

  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 550 / PiecePrice on Request
Minimum Order Quantity10 Piece
Sheath materialSS316
ClassClass 1
Probe length300 mm
Accuracy+/- 1.5 deg C or +/- 0.25%
Probe MaterialStainless Steel
Probe diameter8 mm
InsulationFG/FG/SS
Junction typeGrounded
Temperature Range0 to 1300 deg C
ApplicationIndustrial
Temperature Range :- 0 to 1300°C
  Class :- Class 1

Accuracy :- +/- 1.5 deg C or +/- 0.25%

Application :- Industrial Usage
Assembly :- Thermocouple Probe
Probe Termination :- Miniature Jack

View Complete details

Yes! I am InterestedRequest a call back

Compensating Asbestos Cable

  • Product Image
  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 37.90 / MeterPrice on Request
Minimum Order Quantity100 Meter
Thermocouple TypeKX
Conductor Size1/22
Insulation MaterialFiber Glass
No. Of Cores2 Core
ShieldingFG/Asbestos
Temperature Range-200 to 1260°C
Conductor TypeCopper
Temperature0 to 1250°C
AccuracyClass 1
Cable ColorYellow

Thermocouple asbestos wire refers to thermocouple extension or compensating wires that are insulated with asbestos Fiber, which was historically used due to its excellent heat resistanceelectrical insulation, and durability in harsh environments.

Important Warning

Asbestos is a known carcinogen, and its use is now highly restricted or banned in many countries due to serious health risks (e.g., asbestosis, mesothelioma, lung cancer). Most modern applications have replaced asbestos with safer alternatives such as fiberglass, ceramic Fiber, or mineral insulation.

Description (for historical or legacy context):

  • Purpose: Used to insulate thermocouple wires for high-temperature applications such as kilns, furnaces, or industrial heaters.
  • Temperature Rating: Typically rated for up to 0°C to 1260°C, depending on the construction.
  • Construction:
    • Conductor: Thermocouple wire (Type K, J, T, etc.).
    • Insulation: Layer(s) of asbestos yarn or braid.
    • Outer Sheath (optional): May include asbestos braid or metal shielding.
  • Applications:
    • High-temperature industrial environments
    • Steel mills, foundries, ceramic kilns
    • Legacy systems (not used in modern builds)

Modern Alternatives:

Due to health and regulatory concerns, the following materials are now preferred:

  • Fiberglass Insulation
  • Ceramic Fiber
  • Teflon (for lower temperature ranges)
  • Mineral insulated (MI) cables for extreme conditions

Summary Table

Feature

Thermocouple Asbestos Wire

Insulation

Asbestos Fiber or braid

Temperature Range

0°C to 1260°C

Conductor Types

Type K, J, T, etc.

Hazard

Health risk due to asbestos exposure

Modern Status

Obsolete / Banned in most countries

View Complete details

Yes! I am InterestedRequest a call back

K Type Thermocouple Wire Teflon Coated

  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 23.00 / MeterPrice on Request
Minimum Order Quantity100 Meter
Thermocouple TypeK
Conductor Size7/36
Insulation MaterialPTFE
No. Of Cores2 Core
ShieldingBraided Shield
Temperature Range-200°C to 1250°C
Shielding TypeShielded
Temperature-200 to 1250°C
Outer Sheath MaterialPTFE
Country of OriginMade in India
  • Thermocouple Type K uses a junction between Chromel & Alumel (Nickel-Chromium (Positive) & Nickel Aluminium (Negative)). It is one of the most common general-purpose thermocouples, with a usable temperature range (for the alloy) from about –200 °C to +1,250 °C 
  • The “Teflon coated / Teflon insulated” part means the two wires (Chromium + Aluminium) are insulated by a Teflon polymer This insulation acts as electrical isolation and protective jacket over the bare thermocouple wires.

Construction & Materials

A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:

Component

Material / Type

Purpose / Notes

Conductor / Core wires

Nickel-Chromium (Positive) Nickel Aluminium (Negative)

The thermoelectric pair that produces a voltage proportional to temperature difference

Insulation around each core

Fused PTFE (Teflon)

Electrically isolates the wires; protects from moisture, chemicals, abrasion

Outer jacket / sheath (optional)

FEP, braided shield, or Teflon outer jacket

Additional protection, shielding, mechanical strength

Shield / braid (optional)

Tinned copper or stainless-steel braid, over or under jacket.

To reduce electromagnetic interference (EMI) / noise pickup

View Complete details

Yes! I am InterestedRequest a call back

N Type Thermocouple Cable

  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 32.75 / MeterPrice on Request
Minimum Order Quantity100 Meter
Cable typeN type
Conductor size7/36
No of cores2 core
ClassClass 1
Conductor TypeN Type
ColorOrange
Insulation materialPTFE
Sheath materialPTFE
Cable rating-65°C to 240°C
Temperature-270°C to 1300°C
Type N thermocouple cable is made from Nicrosil (positive leg) and Nisil (negative leg) alloy conductors. It is designed for high-temperature and high-stability applications, providing better accuracy, long-term stability, and oxidation resistance than Type K thermocouples. Type N cables can measure temperatures up to 1300°C, making them suitable for harsh industrial environments such as furnaces, kilns, heat-treating processes, and petrochemical plants. The cable is available with various insulation materials like fiberglass, PTFE, or mineral insulation to suit different temperature and environmental conditions

View Complete details

Yes! I am InterestedRequest a call back

1/24 K Type Thermocouple Cable

  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 38 / MeterPrice on Request
Minimum Order Quantity100 Meter
Cable typeK type
Conductor size0.55mm
No of cores2 core
Insulation materialPTFE
Sheath materialBraided PTFE
Cable rating250 C
ShieldingBraided
BrandRadiant
  • Thermocouple Type K uses a junction between Chromel & Alumel (Nickel-Chromium (Positive) & Nickel Aluminium (Negative)). It is one of the most common general-purpose thermocouples, with a usable temperature range (for the alloy) from about –200 °C to +1,250 °C 
  • The “Teflon coated / Teflon insulated” part means the two wires (Chromium + Aluminium) are insulated by a Teflon polymer This insulation acts as electrical isolation and protective jacket over the bare thermocouple wires.

Construction & Materials

A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:

Component

Material / Type

Purpose / Notes

Conductor / Core wires

Nickel-Chromium (Positive) Nickel Aluminium (Negative)

The thermoelectric pair that produces a voltage proportional to temperature difference

Insulation around each core

Fused PTFE (Teflon)

Electrically isolates the wires; protects from moisture, chemicals, abrasion

Outer jacket / sheath (optional)

FEP, braided shield, or Teflon outer jacket

Additional protection, shielding, mechanical strength

Shield / braid (optional)

Tinned copper or stainless-steel braid, over or under jacket.

To reduce electromagnetic interference (EMI) / noise pickup

View Complete details

Yes! I am InterestedRequest a call back

1/26 K Type Thermocouple Cable

  • Product Image
  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 40 / MeterPrice on Request
Minimum Order Quantity100 Meter
Cable typeK type
Conductor size7/0.2 mm
No of cores2 core
Insulation materialPTFE
Sheath materialPTFE/PTFE
Cable rating250 C
ShieldingBraided
BrandRadiant
  • Thermocouple Type K uses a junction between Chromel & Alumel (Nickel-Chromium (Positive) & Nickel Aluminium (Negative)). It is one of the most common general-purpose thermocouples, with a usable temperature range (for the alloy) from about –200 °C to +1,250 °C 
  • The “Teflon coated / Teflon insulated” part means the two wires (Chromium + Aluminium) are insulated by a Teflon polymer This insulation acts as electrical isolation and protective jacket over the bare thermocouple wires.

Construction & Materials

A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:

Component

Material / Type

Purpose / Notes

Conductor / Core wires

Nickel-Chromium (Positive) Nickel Aluminium (Negative)

The thermoelectric pair that produces a voltage proportional to temperature difference

Insulation around each core

Fused PTFE (Teflon)

Electrically isolates the wires; protects from moisture, chemicals, abrasion

Outer jacket / sheath (optional)

FEP, braided shield, or Teflon outer jacket

Additional protection, shielding, mechanical strength

Shield / braid (optional)

Tinned copper or stainless-steel braid, over or under jacket.

To reduce electromagnetic interference (EMI) / noise pickup

View Complete details

Yes! I am InterestedRequest a call back

1/30 K Type Thermocouple Cable

  • Product Image
  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 42 / MeterPrice on Request
Minimum Order Quantity100 Meter
Thermocouple TypeK
Cable typeK type
No of cores2 core
No. Of Cores2 Core
Sheath materialBraided FG
Temperature Range0 to 1250°C
Cable rating0 to 1250°C
ShieldingBraided
Conductor size1/30
Insulation materialFG/FG
  • Thermocouple Type K uses a junction between Chromel & Alumel (Nickel-Chromium (Positive) & Nickel Aluminium (Negative)). It is one of the most common general-purpose thermocouples, with a usable temperature range (for the alloy) from about –200 °C to +1,250 °C 
  • The “Teflon coated / Teflon insulated” part means the two wires (Chromium + Aluminium) are insulated by a Teflon polymer This insulation acts as electrical isolation and protective jacket over the bare thermocouple wires.

Construction & Materials

A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:

Component

Material / Type

Purpose / Notes

Conductor / Core wires

Nickel-Chromium (Positive) Nickel Aluminium (Negative)

The thermoelectric pair that produces a voltage proportional to temperature difference

Insulation around each core

Fused PTFE (Teflon)

Electrically isolates the wires; protects from moisture, chemicals, abrasion

Outer jacket / sheath (optional)

FEP, braided shield, or Teflon outer jacket

Additional protection, shielding, mechanical strength

Shield / braid (optional)

Tinned copper or stainless-steel braid, over or under jacket.

To reduce electromagnetic interference (EMI) / noise pickup

View Complete details

Yes! I am InterestedRequest a call back

1/22 K Type Thermocouple Cable

  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 36 / MeterPrice on Request
Minimum Order Quantity100 Meter
Cable typeK type
Conductor size7/0.2 mm
No of cores2 core
Insulation materialFG/FG/SS
Sheath materialSS braided, upto 1200°C
Cable rating-200°C to 1260°C
ShieldingBraided
BrandRadiant
  • Thermocouple Type K uses a junction between Chromel & Alumel (Nickel-Chromium (Positive) & Nickel Aluminium (Negative)). It is one of the most common general-purpose thermocouples, with a usable temperature range (for the alloy) from about –200 °C to +1,250 °C 
  • The “Teflon coated / Teflon insulated” part means the two wires (Chromium + Aluminium) are insulated by a Teflon polymer This insulation acts as electrical isolation and protective jacket over the bare thermocouple wires.

Construction & Materials

A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:

Component

Material / Type

Purpose / Notes

Conductor / Core wires

Nickel-Chromium (Positive) Nickel Aluminium (Negative)

The thermoelectric pair that produces a voltage proportional to temperature difference

Insulation around each core

Fused PTFE (Teflon)

Electrically isolates the wires; protects from moisture, chemicals, abrasion

Outer jacket / sheath (optional)

FEP, braided shield, or Teflon outer jacket

Additional protection, shielding, mechanical strength

Shield / braid (optional)

Tinned copper or stainless-steel braid, over or under jacket.

To reduce electromagnetic interference (EMI) / noise pickup

View Complete details

Yes! I am InterestedRequest a call back

3/24 K Type Thermocouple Cable

  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 35 / MeterPrice on Request
Minimum Order Quantity100 Meter
Cable typeK type
Conductor size3/24
No of cores2 core
Insulation materialFG/Asbestos
Sheath materialAsbestos
Cable rating400 C
ShieldingBraided
BrandRadiant
  • Thermocouple Type K uses a junction between Chromel & Alumel (Nickel-Chromium (Positive) & Nickel Aluminium (Negative)). It is one of the most common general-purpose thermocouples, with a usable temperature range (for the alloy) from about –200 °C to +1,250 °C 
  • The “Teflon coated / Teflon insulated” part means the two wires (Chromium + Aluminium) are insulated by a Teflon polymer This insulation acts as electrical isolation and protective jacket over the bare thermocouple wires.

Construction & Materials

A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:

Component

Material / Type

Purpose / Notes

Conductor / Core wires

Nickel-Chromium (Positive) Nickel Aluminium (Negative)

The thermoelectric pair that produces a voltage proportional to temperature difference

Insulation around each core

Fused PTFE (Teflon)

Electrically isolates the wires; protects from moisture, chemicals, abrasion

Outer jacket / sheath (optional)

FEP, braided shield, or Teflon outer jacket

Additional protection, shielding, mechanical strength

Shield / braid (optional)

Tinned copper or stainless-steel braid, over or under jacket.

To reduce electromagnetic interference (EMI) / noise pickup

View Complete details

Yes! I am InterestedRequest a call back

3/26 K Type Thermocouple Cable

  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 40 / MeterPrice on Request
Minimum Order Quantity100 Meter
Cable typeK type
Conductor size3/26
No of cores2 core
Insulation materialFG/FG/SS
Sheath materialSS braided
Cable ratingupto 1200°C
BrandRadiant
  • Thermocouple Type K uses a junction between Chromel & Alumel (Nickel-Chromium (Positive) & Nickel Aluminium (Negative)). It is one of the most common general-purpose thermocouples, with a usable temperature range (for the alloy) from about –200 °C to +1,250 °C 
  • The “Teflon coated / Teflon insulated” part means the two wires (Chromium + Aluminium) are insulated by a Teflon polymer This insulation acts as electrical isolation and protective jacket over the bare thermocouple wires.

Construction & Materials

A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:

Component

Material / Type

Purpose / Notes

Conductor / Core wires

Nickel-Chromium (Positive) Nickel Aluminium (Negative)

The thermoelectric pair that produces a voltage proportional to temperature difference

Insulation around each core

Fused PTFE (Teflon)

Electrically isolates the wires; protects from moisture, chemicals, abrasion

Outer jacket / sheath (optional)

FEP, braided shield, or Teflon outer jacket

Additional protection, shielding, mechanical strength

Shield / braid (optional)

Tinned copper or stainless-steel braid, over or under jacket.

To reduce electromagnetic interference (EMI) / noise pickup

View Complete details

Yes! I am InterestedRequest a call back

7/36 K Type Thermocouple Cable

  • Product Image
  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 30 / MeterPrice on Request
Minimum Order Quantity100 Meter
Cable typeK type
Conductor size7/36
No of cores2 core
Insulation materialFiberglass
Sheath materialSS braided, FG/FG/SS
Cable ratingUp to 1250°C
ShieldingBraided
BrandRadiant
  • Thermocouple Type K uses a junction between Chromel & Alumel (Nickel-Chromium (Positive) & Nickel Aluminium (Negative)). It is one of the most common general-purpose thermocouples, with a usable temperature range (for the alloy) from about –200 °C to +1,250 °C 
  • The “Teflon coated / Teflon insulated” part means the two wires (Chromium + Aluminium) are insulated by a Teflon polymer This insulation acts as electrical isolation and protective jacket over the bare thermocouple wires.

Construction & Materials

A typical K‑type Teflon‑insulated thermocouple wire will be built roughly as follows:

Component

Material / Type

Purpose / Notes

Conductor / Core wires

Nickel-Chromium (Positive) Nickel Aluminium (Negative)

The thermoelectric pair that produces a voltage proportional to temperature difference

Insulation around each core

Fused PTFE (Teflon)

Electrically isolates the wires; protects from moisture, chemicals, abrasion

Outer jacket / sheath (optional)

FEP, braided shield, or Teflon outer jacket

Additional protection, shielding, mechanical strength

Shield / braid (optional)

Tinned copper or stainless-steel braid, over or under jacket.

To reduce electromagnetic interference (EMI) / noise pickup

View Complete details

Yes! I am InterestedRequest a call back

Thermocouple Extension Wire

  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 19.8 / MeterPrice on Request
Minimum Order Quantity100 Meter
Thermocouple TypeKX
Conductor Size3/26
Insulation MaterialFiberglass
Conductor TypeSolid
No. Of Cores2 Core
ShieldingBraided Shield
Temperature Range-200 to 1250°C
Usage/ApplicationElectric
Outer Sheath MaterialSS Braided
Country of OriginMade in India
We are engaged in offering this products to our clients. All our products have been widely appreciated by our customers.  

View Complete details

Yes! I am InterestedRequest a call back

Type K Thermocouple Wire

  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Product Image
Get Best Quote
Rs 22.50 / MeterPrice on Request
Minimum Order Quantity100 Meter
Thermocouple TypeK
Conductor Size7/36
Insulation MaterialFiber Glass
No. Of Cores2 Core
ShieldingFG/FG/SS
Temperature Range-200°C to 1250°C
Shielding TypeShielded
Conductor TypeSolid
Temperature-200 to 1250 deg C
Cable ColorYellow
we are a reputed name in the industry, devoted towards offering the best quality array of K Type Thermocouple Wire And Cables.

Features:
  • Enhanced durability
  • Highly durable
  • Excellent tensile strength

View Complete details